F4010-K is a high-speed optical laser micrometer based on laser diffraction principle.It is fast enough to provide diameter, lumps and necks measurement in 4-axis.
Technology of Simple Structure, Long Durability
F4010-K laser micrometer,adopt laser diffraction measurement method. It has two main characteristics: simple structure, high accuracy.
There is no motor inside, besides, the smart size and simple structure allows easy maintenance work at the later stage Measurement repeatability can reach to ⼟0.1um.
It is applicable to the measurement electric wire&cable, steel wire ,enamelled copper wire, medical hosing,3D filament.,etc. transparent and non-transparent object.

Parameters
| Part No. | F4010-K | ||||
| Axis | 4-axis | ||||
| Sampling Frequency | 40KHz(1-axis :10KHz) | ||||
| Measurement range | 0.5~10mm | ||||
| Repeatability | ±0.1μm | ||||
| Accuracy | diameter accuracy:±(0.001+0.01%*D)mm ovality accuracy: <0.5mm:±0.004mm ≥0.5mm: ±2*(0.001+0.01%*D)mm | ||||
| MIN detectable defect height | 0.01mm | ||||
| Dimensional | 275 x 242 x 60mm | ||||
| Power supply | 24V ±10% 40VA | ||||
| Working temperature | 5~50 ℃ | ||||
| Storage temperature | 0~60℃ | ||||
| Relative humidity | Maximum 95%, no condensation | ||||
| Display | LED display | ||||
| Communication port | Standard: RS485 Modbus-RTU,CAN,WIFI Option: PROFIBUS, PROFINET,EtherNet/IP,EtherCAT | ||||
| Electrical port | Standard: digital output(relay),digital input,analog input,encoder pulse input port Option:PI feedback control | ||||
| Data collection and analysis | available (option DS14 ZT display and control system) | ||||
| Out-of-tolerance | available | ||||
| Transparent mode | available | ||||